6″ V-TECH – Ventilated Firestop Plate (Solid Fuel) – 152 Ø

£41.99

The Ventilated Firestop must be used on solid fuel appliances.
A Firestop plate is used to allow the chimney to pass between floors, for example, when you need the chimney to go through the ceiling on the ground floor through to the first floor.

Category:

The Ventilated Firestop must be used on solid fuel appliances.
A Firestop plate is used to allow the chimney to pass between floors, for example, when you need the chimney to go through the ceiling on the ground floor through to the first floor.
The steel plate is designed to provide the appropriate distance between the flue and the adjacent flamable materials, according to both fire and building regulations. It is attached to the underside of the ceiling. If you are going through a second ceiling then you should use a second Firestop plate on the floor and again on the first floor ceiling.
You should use a Ventilated Firestop when the installed appliance will burn solid fuels, for example wood, coal, etc.
A Non-Ventilated Firestop plate can be used on installations burning gas or oil.
This item is non load-bearing.
WHAT IS IN THE BOX
1) 1 x Ventilated Fire Stop Plate with upstand for mounting under the ceiling.
2) 1 x Ventilated Fire Stop Plate that is non-loadbearing for mounting on the floor above.

APPLICATION
For use on solid fuel and gas/oil appliances. eg: woodstoves, gas coal effect fires, oil boiler and any solid fuel appliances.

CONSTRUCTION
Outer skin is made from 304 grade stainless steel and is 0.4mm thick. Inner skin is made from 316 grade stainless steel and is 0.4mm thick. Insulation is compressed rockwool giving a density of 230kgper cubic metre. The insulation is encapsulated within the twist-lock couplers. All parts are fully laser welded.
Distance to combustibles is 50mm.

APPROVALS
V-TECH is HETAS Approved and is CE marked.
Designation Number
EN1856-1 T450 N1 D V2 L50040 G(50).

INSTALLATION
V-TECH Twin Wall Insulated Chimney parts are secured together by twisting two pieces together until they lock, then secure using the provided locking band.
Make sure that you keep a distance of 50mm from the outside of the flue to any combustible material (wood, plaster board).

Reviews

There are no reviews yet.

Be the first to review “6″ V-TECH – Ventilated Firestop Plate (Solid Fuel) – 152 Ø”

Your email address will not be published. Required fields are marked *

Shopping Cart